Disc Stack Centrifuge Troubleshooting

A disc centrifuge, also known as a disc stack centrifuge, is a high-speed mechanical device used for the separation of liquids and solids in industrial processes. These machines operate on the principle of centrifugal force and are widely used in industries such as pharmaceuticals, biotechnology, food and beverage, marine, and petrochemicals. The stack of conical discs inside the bowl of the centrifuge dramatically increases the separation surface area, making the separation process highly efficient.

However, like any mechanical system, disc stack centrifuges can encounter operational issues that affect performance, particularly with the bowl opening and closing mechanisms. This article provides an in-depth guide to troubleshooting these issues, focusing on the fail to close and fail to open scenarios, their causes, symptoms, and corrective actions.

Disc Stack Centrifuge Bowl Opening and Closing Operation

The efficient operation of a disc centrifuge depends heavily on the proper functioning of its bowl — specifically, its ability to open and close at the right times during operation. Here's a breakdown of how these processes should work under normal conditions.

Bowl Closing Process

The bowl closing process in a disc stack centrifuge involves the use of hydraulic pressure. Closing water is pumped into a chamber beneath the operating slide, a movable component inside the bowl. As this chamber fills with water, the operating slide moves upward, pushing the sludge discharge ports closed. This sealing action enables the centrifuge to build up the required internal pressure during operation.

Key parameters during bowl closing include:

  • Closing water volume (typically between 0.3 to 0.5 liters)

  • Closing pressure (generally 4 to 6 bar, depending on the machine model)

  • Bowl speed (must be at operational RPM, e.g., 7,000 to 9,000 RPM)

Bowl Opening Process

The bowl opening process, often referred to as a "shoot", occurs when the centrifuge ejects accumulated sludge. This process involves injecting opening water into a different chamber, which pushes the operating slide downward, opening the sludge ports momentarily.

Key parameters during bowl opening:

  • Opening water volume (typically 0.3 to 0.6 liters)

  • Opening pressure (4 to 6 bar)

  • Timing: Must be synchronized with process cycle

Bowl Closing Process After Sludge Ejection

After sludge ejection, the bowl must close again to resume normal separation. This is a critical step — any failure here can lead to process interruption or even machine damage. The closing water must again be injected to push the slide upward and seal the ports.

Telltale Signs of Bowl Not Closing

A disc centrifuge bowl that fails to close properly can result in:

  • Product leakage

  • Low separation efficiency

  • Unusual vibrations

  • Alarming sound or error codes from the PLC

  • Sludge ejection occurring too frequently or not at all

Operators may also notice that the centrifuge takes longer to reach operational pressure or fails to maintain it, indicating that the bowl is not sealing properly.

Reasons and Fixes for Bowl Not Closing (aka Fail to Close)

Issues with the Closing Water System

The closing water system is the hydraulic power source for the bowl's sealing mechanism. Problems may include:

  • Pump failure

  • Blocked or kinked hoses

  • Air in the water line

  • Incorrect water temperature

Fix: Inspect the entire water system for leaks, blockages, and pump performance. Use degassed water and ensure the system is primed to remove air.

Closing Water Flow Rate (Volume)

Insufficient closing water volume can prevent the operating slide from moving fully up.

ParameterStandard ValueFault Indication
Water Volume0.3 – 0.5 LSlide not moving fully
Flow Rate5 – 10 L/minDelayed or failed closing

Fix: Calibrate the dosing system or adjust the solenoid valve timing.

Closing Water Pressure

Even if the volume is correct, insufficient closing water pressure will prevent proper slide movement.

Fix: Check for pressure regulator malfunction or pump degradation. Pressure should be steady between 4–6 bar.

Condition of Drain Valve Plugs

Worn or damaged valve plugs can leak water meant for closing, reducing effective hydraulic pressure.

Fix: Inspect and replace valve plugs routinely as part of preventive maintenance.

Condition of the Distributing Ring and O-Ring Around It

The distributing ring channels water inside the bowl. If the O-ring around it is worn, water may leak internally.

Fix: Replace the O-ring and inspect the distributing ring for cracks or warping.

Gasket Under the Control Paring Disc is Worn or Damaged

The control paring disc helps regulate internal pressure. A worn gasket beneath it can cause pressure loss.

Fix: Replace the gasket and ensure all mating surfaces are clean and smooth.

Centrifuge Bowl Speed Too Low

A slow bowl speed means insufficient centrifugal force to assist in slide movement.

Fix: Ensure the drive motor is functioning properly and the VFD (variable frequency drive) is properly tuned.

Operating Signs to Bowl not Opening or Fail to Shoot

When the bowl fails to open correctly (also known as fail to shoot), the following symptoms are often observed:

  • Sludge builds up without discharge

  • Increased vibration levels

  • Reduced throughput or separation quality

  • PLC alarm indicating missed shoot

  • Visible sludge in the separated liquid output

These signs indicate that sludge is not being removed from the bowl, leading to reduced efficiency and potential mechanical overload.

Causes and Fixes for Bowl Not Opening (aka Fail to Shoot)

Issues with the Opening Water System

Just like the closing system, the opening water system must deliver water at the right time, pressure, and volume.

Fix: Check for airlocks, blocked lines, leaking solenoids, or pump malfunction.

Opening Water Flow-Rate (Volume)

Inadequate opening water volume results in incomplete slide movement.

ParameterStandard ValueFault Indication
Water Volume0.3 – 0.6 LPorts not opening fully
Flow Rate5 – 12 L/minDelayed or failed shoot

Fix: Adjust dosing system and verify solenoid valve actuation time.

Opening Water Pressure

Low pressure can prevent the slide from descending fully to open the ports.

Fix: Inspect and maintain the pressure pump. Ensure filters are clean and valves are not clogged.

Mineral Deposits in the Opening Water Chamber (Operating Slide)

Hard water can lead to scale buildup inside the slide chamber, restricting movement.

Fix: Regularly descale with citric acid or approved cleaning solutions and use demineralized water if possible.

Operating Slide Seal Ring

A worn or cracked seal ring can cause internal leaks during the opening cycle, reducing effective pressure.

Fix: Replace the seal ring during scheduled maintenance and inspect the slide surface for wear.

Automatic Detection of Bowl Not Closing or Bowl Not Opening

Modern disc stack centrifuges are equipped with PLC-based monitoring systems that detect abnormal conditions such as:

  • Pressure drops

  • Delayed slide movement

  • Missed shoot cycles

  • Vibration anomalies

These systems use sensors and timers to compare actual vs expected performance, triggering alarms or stopping the process when anomalies are detected. Some advanced systems even log historical data for trend analysis.

FeatureDetects Fail to CloseDetects Fail to OpenAction
Pressure SensorAlarm & shutdown
Vibration MonitoringTrigger alarm
Shoot CounterMissed shoot alert
Slide Position SensorDirect feedback

Conclusion

A disc centrifuge is a workhorse in many industrial processes, and its performance is highly dependent on the integrity and functionality of its bowl opening and closing systems. Troubleshooting a fail to close or fail to shoot condition involves understanding the interplay of hydraulic systems, mechanical seals, pressure dynamics, and control logic.

With the latest trends in automation and predictive maintenance, operators can now monitor and prevent many of these issues before they cause unscheduled downtime. By maintaining optimal conditions for water pressure, flow, and component integrity, businesses can ensure maximum uptime and separation efficiency from their disc stack centrifuge systems.

FAQs

Q1: What is the ideal pressure for closing water in a disc centrifuge?
Typically 4 to 6 bar, but always refer to the manufacturer's specifications.

Q2: Can I use tap water for the opening/closing systems?
Not recommended. Use softened or demineralized water to avoid scale buildup.

Q3: How often should the operating slide seal ring be replaced?
Every 6 to 12 months, depending on operation frequency and water quality.

Q4: Why does my bowl not close even though pressure and volume are correct?
Check for worn O-rings, drain plugs, and gaskets — even minor leaks can prevent full slide movement.

Q5: Can I automate bowl opening cycles?
Yes, most modern disc stack centrifuges support PLC integration for fully automated shoot cycles.

Q6: What's the difference between a disc centrifuge and a decanter centrifuge?
A disc centrifuge uses a stack of conical discs and is better for fine separation at high speeds, while a decanter uses an auger and is better suited for high-solid content.


LEARN MORE PRODUCTS

If you are interested in our products or have any questions, please feel free to contact us.
We are one of the world’s leading manufacturers of decanter centrifuge,disc centrifuge,tubular centrifuge,separation systems and drying equipment.

QUICK LINKS

PRODUCT CATEGORY

CONTACT US

Tel: +86-419-416-0500
Mobile:8615941954210
             8618041915856
E-mail: megan@lnszjx.com
Address: No188,Shuxi Road,Wucheng District,Jinhua City China
Leave a Message
Copyright © 2023 SHENZHOU Co., Ltd. All Rights Reserved. Support by LeadongSitemap. Privacy Policy